top of page

Electric Tugs Are Arriving: The Risk and Insurance Questions Worth Asking Now

Writer: Richard Young
Richard Young
5 days ago
12 min read
Tugs in canal view

The first of eight electric ship-assist tugs built for the ports of Los Angeles and Long Beach is in sea trials in Seattle and due in Southern California in December.


That is a fleet, not a demonstration. It is also a propulsion technology that United States regulations do not cover prescriptively, that carries a fire risk profile different from a conventional engine room, and whose insurance treatment involves questions worth settling at placement rather than at claim.


What Is Being Built

Curtin Maritime’s first tug of the series, the Tuuli C, is in sea trials at Snow & Company in Seattle, the first of eight for Los Angeles and Long Beach under the Curtin Harbor Services brand. She launched on 5 May 2026, with sea trials beginning in October.


The Vessel: An ASD tractor tug, 80 feet 9 inches by 42 feet 3 inches, with two 2,000 horsepower Schottel L-drive azimuth units. The propulsion plant is designed to deliver more than 4,000 horsepower and 55 short tons of bollard pull. Energy is stored in a 6 MWh lithium iron phosphate battery system supplied and integrated by Arc of Los Angeles, which also provides the battery management system. The battery room is protected by a Marioff HI-FOG water mist system, consistent with the Coast Guard’s emphasis on water-based suppression and cooling for integrated lithium-ion installations.


The Fleet is not Uniform: Curtin describes three classes covering the range of ship-assist work: 55-ton bollard pull for standard container and cargo vessels, 70-ton for larger ships, and a 100-ton class for the heaviest jobs. Hulls 1 and 2 are 55-ton, hulls 3 and 4 are 70-ton, and construction on hulls 5 to 8 starts in mid to late 2027. The specification above is the 55-ton boat.


The Configuration: The terminology has shifted during the program. Arc’s September 2025 announcement described hybrid-electric vessels, while Curtin’s current materials describe battery-electric tugs with zero exhaust at the point of operation and no diesel combustion. A South Coast AQMD funding proposal of April 2026 has been reported as describing removable emergency diesel generators for certain vessels in the program. The publicly available descriptions do not conclusively establish the final as-built machinery arrangement of any individual hull. For an insurer that is the point. What has to be assessed and insured is the approved arrangement, not the program description.


The Capacity: Each vessel carries a 6 MWh battery pack, sized to support a full working day of escorting and docking with reserve capacity, and built with redundancy allowing continued safe operation if portions of the system are offline. Curtin says sea trial data now being collected will provide endurance figures under real operating conditions, so treat the working-day figure as the design objective rather than demonstrated performance.


The Money and the Schedule: Curtin has committed around $200 million across the vessels and charging infrastructure, and holds a 50 percent stake in the shipyard. A separately announced agreement with Arc, dated September 2025, is valued at approximately $160 million. Curtin’s current deployment schedule targets four tugs in service by the first quarter of 2028 and all eight by the fourth quarter of 2029, with Tuuli C arriving in Southern California in December 2026.


The Charging: Existing 480V/400A shore power at both ports supports overnight charging from the start, with no new infrastructure needed to begin. Curtin is building one permanent facility per port. The Los Angeles site at Berth 56 and AltaSea is in plan check with LADWP and the Department of Building and Safety, centered on a barge carrying a 10 MWh battery storage system and four megawatt charging system fast chargers, with the 10 MWh buffer intended to keep energy available during micro grid maintenance. Fast charging at Los Angeles targets the first or second quarter of 2027, and the Long Beach site is in planning. The micro grids are designed for self-generation powered by natural gas or hydrogen so the program adds no load to the grid. A full charge takes approximately 2.5 to 3 hours on megawatt-class chargers, and the vessels have both AC and DC inlets. Motive Energy is the charging partner.


The Build: Snow is constructing each tug in nineteen modules, built separately and joined, including hull sections, battery room and deckhouse. The second vessel, Tigerlily C, launched on 18 August 2026.


The Context: California Air Resources Board rules on harbor craft are the commercial driver, and Curtin is pursuing a CARB Best Available Control Technology designation for battery-electric harbor tugs, which if granted would make it the standard every new tug in California must meet. Curtin already operates the Isla C, a purpose-built electric push boat built by Snow & Co to assist dredgers. Crowley’s eWolf, the first battery-electric tug built in the United States, entered service at the Port of San Diego in 2024.


The Conversion Route

The newbuilds are one path. The other is the decision an existing operator might actually face.


Arc and the naval architects Glosten have begun engineering a battery-electric conversion of the Harbor Sentinel, a harbor tug built in 1975 and owned by Pacific Maritime Group. Her twin Cummins KT19 main engines, producing 708 kW combined, come out, replaced by an Arc electric powertrain and a 2 MWh battery bank over a twelve-month project. The tug then returns to work from PMG’s Long Beach terminal for a twelve-month demonstration.


Funding comes from the Port of Long Beach Technology Advancement Program and SWIFT Program, with a Volkswagen Environmental Mitigation Trust grant administered by the Bay Area Air Quality Management District.


A conversion raises harder questions than a newbuild. A new vessel is designed around its energy system from the first module. A conversion puts a novel power plant into a fifty-year-old hull with an existing survey history, an existing certification position, and an insurance placement underwritten on a diesel boat.


Why a Battery Fire Is Different

A diesel machinery space fire presents familiar hazards with established procedures. Lithium-ion battery failures present different ones.


Thermal runaway can propagate from one cell to adjacent cells, releasing substantial heat together with flammable and toxic gases. The severity and the mechanisms vary by chemistry. The lithium iron phosphate cells used here are generally more thermally stable than nickel-rich lithium-ion chemistries and, unlike several other chemistries, may not release oxygen from cathode decomposition. They are not immune to thermal runaway, and they can release significant quantities of flammable gas.


The Coast Guard’s framing in Safety Alert 14-25 is that lithium-ion batteries are used on vessels for their energy density, and that the same characteristic increases risk during a fire.


The practical consequence is that detection, containment, cooling and prevention of propagation sit at the center of battery system fire protection, rather than conventional extinguishing. That is reflected in the Coast Guard’s expectation of water-based fixed fire suppression and in the water mist system installed aboard the Tuuli C.


The Coast Guard Framework, and What Is Actually Binding

There is no comprehensive prescriptive regulation for battery-powered commercial vessels in the Code of Federal Regulations. What exists is design guidance applied through plan review and equivalency, and the distinction between guidance and binding requirement matters.


CG-ENG Policy Letter 02-19 is guidance. Issued in October 2019 and titled Design Guidance for Lithium-Ion Battery Installations Onboard Commercial Vessels, it applies to lithium-ion installations used for propulsion or electrical power on all commercial vessels and should be followed for vessels whose construction started after 2 October 2019. It covers battery system design including battery management system requirements and incorporates ASTM F3353-19, the Standard Guide for Shipboard Use of Lithium-Ion Batteries. It sets out the Coast Guard’s accepted approach, including qualitative failure analysis, design verification testing and periodic safety testing documentation. It is not itself a regulation.


The binding route runs through equivalency. For a Subchapter M towing vessel the authority is 46 CFR 143.210, which provides that systems of a novel design that cannot be reviewed in accordance with that part must be approved by the Marine Safety Center as providing an equivalent level of safety. The Marine Safety Center’s plan review guideline states this is typically accomplished by meeting the requirements for a Subchapter T vessel in Policy Letter 02-19, and that equivalencies are submitted through the cognizant Officer in Charge, Marine Inspection under 46 CFR 136.115.


The legal obligation comes from the regulation. Policy Letter 02-19 provides a commonly accepted means of demonstrating equivalent safety, but alternative arrangements may be proposed and approved by the Marine Safety Center.


Plan review for integrated systems. The Coast Guard’s position in Safety Alert 14-25 is that all integrated lithium-ion battery systems on inspected vessels must undergo engineering plan review, be fitted with supporting safety systems, be tested and inspected at installation and periodically afterward, and be properly maintained by competent mariners, regardless of battery bank size. Integrated means hardwired to power the ship’s electrical loads. Batteries carried as cargo or plug-in equipment are a separate question, addressed for small passenger vessels by CG-CVC Policy Letter 20-03.


Design verification testing. A Design Verification Test Procedure tests the assumptions in the design, and the Marine Safety Center publishes plan review guidelines for developing one for lithium-ion systems. The Coast Guard’s guidance is that plan review and design testing should be completed early in construction, and that if they are not approved by delivery, marine inspectors may require the review to be completed through the Marine Safety Center. For an operator with a delivery date, that is a schedule exposure.


Class rules are not automatically accepted. The Marine Safety Center, working with CG-ENG and CG-CVC, reviews requests from recognized organizations for acceptance of their class rules as equivalent to Policy Letter 02-19 on a case-by-case basis.


The Design Basis Agreement. For genuinely novel or highly complex designs, a DBA allows the Coast Guard and the applicant to evaluate and document alternative acceptable arrangements in advance, relying on the Coast Guard’s equivalency authorities. The process is set out in CG-ENG Policy Letter 01-23, and the Coast Guard identifies novel and emerging technologies, expressly including lithium-ion battery installations, as the circumstances where it applies. Equivalency requests go to the Coast Guard’s flag state control address, with CG-CVC coordinating and CG-ENG leading the review.


What the Coast Guard’s Casualty Tells You

Safety Alert 14-25, released in July 2025, was prompted by an incident worth noting precisely because it was unremarkable.


An integrated lithium-ion battery bank caught fire aboard an inspected passenger vessel when loosely crimped lugs overheated. Nobody was injured and the vessel sustained minimal damage.


That is the failure mode. A bad crimp on a terminal. Whether the underlying cause was installation workmanship, inspection, maintenance or quality control is not established in the alert, and all of those are management questions as much as technical ones.


The alert lists the elements the Coast Guard expects to see addressing battery hazards: ship-specific risk and safety assessments, battery management systems, qualitative failure analyses for vital ship systems, design verification test procedures, periodic inspection, protection, fire, smoke and gas detection, and water-based fixed fire suppression.


It also makes an identification point that applies to any vessel. Packaged lithium-ion batteries often visually resemble traditional lead acid batteries, which makes verifying the nameplate specification essential.


Hull and Machinery: What to Raise at Placement

Established marine insurance principles continue to apply. What is new is the technical and valuation information an underwriter needs, and some of it may call for specific wording or endorsement.


The machinery is a different kind of asset. On a conventional tug the engines are a large share of value with a well-understood repair proposition. Here a large share sits in the battery system, and the repair and replacement economics differ.


Partial loss assessment is less established. Where a battery system suffers a thermal event affecting part of the installation, the questions of what is repairable, what must be replaced for safety reasons, and what the residual life of undamaged modules is do not have decades of survey practice behind them.


Constructive total loss deserves scrutiny. Concentration of value in the battery and propulsion systems could make severe damage to them disproportionately expensive to repair, particularly where whole modules or integrated systems need replacing. Whether that produces a CTL depends on the hull conditions, the insured value and the estimated cost of recovery and repair, so it is a calculation to run rather than an assumption to make.


Charging is a defined operating state. Insurers have long dealt with shore power connections and electrical machinery. What is newer is the scale of battery dependency, megawatt-class fast charging, and the concentration of risk during charging. Where that state sits relative to port risk and any trading or laid-up provisions is worth confirming.


P&I and Liability

Crew exposure differs. Thermal events produce toxic gases, and a battery room fire presents a confined space and atmosphere problem alongside a fire problem. Training, drills and protective equipment differ from a machinery space fire, which connects to the enclosed space issues we covered previously.


Shoreside response capability. A port fire service responding to a battery fire aboard a tug needs to know it is one and needs the right approach. Whether local responders have that knowledge is worth establishing before it is needed.


Liability allocation with the charging provider. Where the charging infrastructure is supplied or operated by another party, a fault during charging raises questions about whose negligence caused it and what the contract says. That allocation should be in writing, and it is the kind of exposure that falls between policies when nobody has looked.


The charging asset is itself a large insurable exposure. A barge carrying 10 MWh of battery storage and four megawatt chargers, with a natural gas or hydrogen fuelled micro grid, is a significant installation in its own right. Whoever owns it has a property, business interruption and liability exposure separate from the tugs, and the tugs’ availability depends on it.


Availability, Loss of Hire and the Charging Dependency

The vessel design answers part of this. The battery is sized for a full working day with reserve and built with redundancy allowing continued safe operation with portions offline, which is the kind of thing an underwriter should be asking about rather than assuming.


The wider question is not the boat. A tug dependent on shore power is dependent on a shoreside asset it may not own. If that asset fails, the vessel is undamaged, not off hire for any conventional reason, and unable to work.


Standard loss of hire cover responds to specified insured events, commonly physical damage to the vessel, so a shoreside power failure would not ordinarily trigger it. The analogy to the alternative fuel bunkering piece is close: the vessel is fine, the energy is not available, and the policy that normally answers an earnings interruption does not reach it. Whether contingent business interruption or a tailored arrangement is available and appropriate is a question to put to your broker rather than an exposure to accept.


For Operators Considering This

Start the regulatory conversation first. Plan review, design verification testing and any equivalency determination drive the schedule. Policy Letter 02-19 is the guidance, the Marine Safety Center is the reviewer, and for a towing vessel the 46 CFR 143.210 route runs through your OCMI.


Do not assume class rules satisfy the Coast Guard. Acceptance as equivalent to Policy Letter 02-19 is decided case by case.


Consider a Design Basis Agreement for anything unusual. It documents what the Coast Guard will accept before you build to it.


Establish the actual machinery arrangement, not the marketing description. Emergency generation, if fitted, carries its own fuel system, maintenance obligations and valuation consequences.


Talk to your hull underwriter and your club before you order or convert. The questions above do not have standard answers yet, which means they are negotiable, and the time is before the asset exists.


Get the maintenance and inspection regime right and record it. Periodic testing after installation is a Coast Guard expectation, and connections and terminations deserve particular attention.


Train for the right fire, and for the right boat. Curtin’s chief executive has put the operational point plainly: the biggest hurdle is the status quo, crews are used to diesel tug profiles, and electric tugs require new operating habits, with training and education the key.


Establish shoreside response capability. Talk to the port and the fire service about what they would do.


Write down the charging liability allocation.


Think about availability, not just casualty. The charging dependency is a commercial exposure that may need its own arrangement.


Charter and lease structures are available now. Curtin says it is already in charter discussions with other operators and has offered four contracting structures, and is open to direct charters, leases, partnerships and vessel sales. An operator facing CARB harbor craft requirements does not necessarily have to own one of these to use one, and the insurance and liability allocation under a charter of an electric tug is a question with no standard answer yet.


The Bottom Line

Eight electric ship-assist tugs for Los Angeles and Long Beach across three bollard pull classes, around $200 million committed, the first in trials and due south in December, four targeted for service by the first quarter of 2028 and all eight by the fourth quarter of 2029, with a fifty-year-old tug being converted alongside them. This is past the pilot stage.


The regulatory position is workable but not comprehensively prescriptive. Policy Letter 02-19 provides the Coast Guard’s accepted design guidance, including failure analysis, design verification and periodic safety testing. For a Subchapter M towing vessel, battery propulsion can require Marine Safety Center approval under the novel design provisions of 46 CFR 143.210, with equivalency submitted through the cognizant OCMI, and alternatives to the policy letter may be proposed. The approval conditions determine the specific requirements, and complex designs may warrant a Design Basis Agreement.


The risk is not that these vessels are unsafe. The designs address the known hazards directly, with water mist in the battery room, a battery management system, redundancy and sizing for a working day with reserve. The point is that the technical and valuation questions around partial loss, charging-state exposure, liability allocation with charging providers and availability when a shoreside asset fails need to be worked through at placement, when they can still be negotiated.

The casualty that prompted the Coast Guard’s safety alert came from a loose crimp. The technology is new and the failure modes often will not be.

bottom of page